摘要:针对国内的电力迅猛发展,为进一步节能减排,提出了在电厂应用中压变频。本文介绍了冷凝泵在电厂的运行工况,分析了水泵的变频节能原理。对珞璜电厂的变频改造提出了系统方案,包括系统的动力方案和系统的控制方案。着重介绍了ACS5000中压变频器的拓扑结构、技术特点和控制方式。最后通过电厂的实测数据证明了ACS5000中压变频系统具有很高的系统动、静态性能,净节电率超过40%。
关键字:中压变频器;ACS5000;直接转矩控制;IGCT;电厂;冷凝泵
Application Analysis of ABB ACS5000 MV Drives in Luohuang Power Plant
Guan Eryong1, Peng Jingtao2, Jin Shi1, Wu Shaobin2
1. ABB Beijing drive systems Co., Ltd. 100015
2. Chongqing Luohuang Power Plant of Huaneng group 402283
Abstract:For the domestic development of electrical power, MV (medium voltage) drives are proposed in power plant to deeply save energy. This paper introduces the operation condition of condensation pump and saving principle with MV drives. A system scheme including system power scheme and system control scheme, is put forward to retrofit the Luohuang power plant. This paper presents in detail the topology configuration, technical feature and control scheme of ACS5000 MV drives. According to the data in real running derived from power plant, ACS5000 MV drives is verified to be with excellent static and dynamic performance, and also save energy much more than 40%.
Keyword:MV drives;ACS5000;DTC;IGCT;Power plant;Condensation pump
1.引言(Introduction)
随着国民经济的蓬勃发展,对于电力的需求日益增加,全国电力工业一直保持着快速增长的势头。截至2006年底,我国电力工业全国发电装机容量达到6.22亿千瓦,同比增长20.3%。火电达到4.84亿千瓦,约占总容量77.82%,同比增长23.7%;而这一数字到2007年底已经达到了7.13亿千瓦,预计到今年年底,全国电力装机容量将突破8亿千瓦,而其中火电机组将占到78%[1]。
随着大批电源项目的相继建成投产,电力供需形势进一步缓和,发电设备利用小时数大幅回落。从2006年开始,全国加快电源结构调整,优化节能环保经济调度,加大科学、精细和对标管理实施力度,电力行业节能降耗取得持续进展。2006年全国供电煤耗为366克/千瓦时,比2005年降低4克/千瓦时;电网输电线路损失率比去年减少0.1个百分点,降为7.08%。
由于电力生产的特殊性,决定了电力生产系统中的各种设备需要根据最大生产能力来进行配置,而不能根据平均的电力需求配置系统[2]。在电力生产中,电力生产的最大生产能力是是根据主机(锅炉、汽轮机和发电机)的出力决定的,辅机(各种风机、水泵及其驱动电机、电气控制调节系统等)是根据主机的情况配置的。在设计过程中均考虑一定的裕量,因此造成在实际运行中,多少风机和水泵均需要调节。传统的流量调节方式是节流,但是存在反应慢、调节精度低、能耗大等问题,而中压变频因其调节性能优良、节能效果好等因素,正逐渐应用到电厂中风机、水泵等流量调节中[3-4]。
通过近几年的中压变频应用情况的统计分析可以看出,发电厂中冷凝泵辅机具有很大的变频节能空间和应用前景。
重庆美电电器变频器批发维修中心,专业,优质,快速,诚信是企业精!ABB,富士,安川,台达,森兰,德弗,科润,等售前售后服务中心,24小时服务电话13883244118.。